Installation Instructions

Installation details for AlphaResiliant™ Isolation Clips Part #ARISC-1
Print Data Sheet
ALPHARESILIENT™ SOUND ISOLATION CLIP:
· Spacing maximum 48" on center
· Splice Hat Track with 6" overlap
· Secure with screws
· Maximum allowable dead load 36 lbs. per
ARSIC-1 clip
HAT TRACK: Minimum requirements:
· 25 gauge (.0188" thickness)
· Hemmed edge detail on all 25 gauge
· Optional: 22 gauge (0.027 inch thickness)or
20 gauge (0.033 inch thickness)
· Depth 7/8" or 1 1/2"
· Width Top 2 3/8" wide
· Bottom 1 1/4" wide
FASTENERS:
· ARSIC-1 to wood 2 1/4" (57mm) minimum
length type "W" screw
· ARSIC-1 to steel 1 5/8" (41mm) minimum
length type "S" screw
· DO NOT fasten ARSIC-1 to framing
members with nails. Use only approved
screws
· Drywall to Hat Track: (all use Type "S" screw
with bugle head)
single layer 1/2" (12mm) use: 1 1/8" (28mm)
single layer 5/8" (16mm) use: 1 1/4" (32mm)
second layer 1/2" (12mm) use: 1 5/8" (41mm)
second layer 5/8" (16mm) use: 1 5/8"(41mm)
WALL MOUNT:
· Apply AudioSeal™ Sound Barrier (AB10NR)
to framing as shown in black
· Apply Hat Track perpendicular (at right
angles) to AB10NR.
· Space Hat Track 24" (600mm) on center
maximum
· ARSIC-1 Clip to be 48" (1219mm) on center
Maximum
· Locate first track within 2" (50mm) from floor
and with in 6" (150mm) from ceiling

 

Acoustical Solutions, Inc
Ph: 800-782-5742 Fax: 804-346-8808