Install Directions for PolyPhon™ Acoustical Panels
Acoustical wall panels may be attached to walls with a variety of hardware:
Z-Clips
If the wall panels are designed to be removable, the use of Z-clips and/or Zbars may be used for installation.
- Z-clips are factory installed on the back of the panels and z-bar, or additional zclips are sent in a shipping package to be installed on the wall where the panels are to be installed.
Step 1:
- Determine the Z-clip or Z-bar locations on the wall to line up with the Z-clip locations on the wall panels. (This "top" of this location is calculated by adding the "z-clip location on panel" to the distance from the top of the wall to the top of the panel.)
- Secure the Z-clip or Z-bar and washers to the wall with 2 screws. (Place 1 washer between the wall and Z-clip or Z-bar at each screw location).
- Slide the Z-clips on the panels onto the Z-clips or Z-bars on the wall.
|
 Step 2:
Lay out the panel locations. Determine z-clip or z-bar location on wall to line up with z-clip location on panels.
Step 3:
Secure the z-clip or z-bar to the wall with 2 screws.
Step 4:
Slide the z-clips on the panels onto the z-clips or z-bars on the wall.
*For vaulted or sloped ceilings, apply a small amount of adhesive (ie) LIQUID NAILS on both sides of clips.
|
 |
Impaling Pin
- Mount Pins to the wall surface by removing the paper backing and pressing the pin's flat backing FIRMLY ONTO WALL.
- Pins should be located on the wall to avoid the fabric on the back of the panel
- Apply a golf-ball size amount of panel adhesive on the wall surface next to each pin
- Push the panel onto the pins using firm pressure with the palm of your hand in the area around each pin
Number of Pins per Panel
|
|

|
Panel Length |
Number of Pins |
| Up to 24' |
4 |
| 24' to 48' |
4-6 |
| 48' to 72' |
6-8 |
| 72' to 96' |
6-8 |
| 96' to 120' |
10 |